Encorp paralleling switchgear is designed to be used as a peak-shaving control system that allows the generator to operate only when the utility is available. Encorp switchgear includes an integrated control, display and circuit breaker panel. The generator can synchronize individually on and off to the power source in a soft transition mode, supplementing utility power to perform a peak-shaving operation.
Encorp switchgear may command the generator to start by receiving a signal from the software located off site. Once the signal is received, Encorp switchgear will automatically start the generator, bring it to rated speed (50/60 Hz), synchronize it to the utility and then softload the generator to a predetermined base-load set point. The generator will remain paralleled to the utility until a signal is received to end the peak-shaving operation. When the remote signal is received to stop the generator, the switchgear will soft unload the generator, open the generator breaker, and cool down the engine for a set time period before shutting off.
Encorp switchgear may command the generator to start by receiving a signal from the remote devices located off site.
Encorp paralleling switchgear is designed to be used as a peak shaving control system that allows the generator to operate when the utility is available or in island mode.
The generator may be started manually while standing next to the generator. This manual operation may be initiated by putting the switch on the front panel into the “RUN” position and pushing the “START” button on the HMI. This will start the generator, automatically synchronize it to the utility, close the generator breaker, softload the generator to a predetermined base-load point and remain paralleled to the utility. When the switch on the front panel is put back into the “OFF” position, the switchgear will soft unload the generator, open the generator breaker, cool down and shut off the generator.
At a selected start time and/or set demand level, the switchgear will automatically start the generator, synchronize it to the utility, close the generator breaker, softload it to a predetermined base-load set point and remain paralleled to the utility. At the selected shut-down time and/or minimum demand level, the switchgear will automatically soft unload the generator, open the generator breaker and cool down and shut off the engine.
CORPORATE HEADQUARTERS
242 Linden Street
Fort Collins, CO 80524
Main 970.674.5300
sales@encorp.com
Technical Support:
techsupport@encorp.com
24-Hour Service 888.362.6771
Employment:
info@encorp.com
New York City
405 Lexington Avenue
New York City, NY 10174
California
2121 N. California Blvd.
Suite 290
Walnut Creek, CA 94596
Hawaii
500 Ala Moana Blvd
Suite 7400
Honolulu, HI 96813
Germany
Königsallee 92a
40212 Düsseldorf, Germany
Copyright © 2022 Encorp. All Rights Reserved.